Zhongzheng Boiler CO.; Ltd is a leading industrial horizontal boiler manufacturer and exporter in Henan Province, China .We produces 4 series of more than 200 kinds of products, which can provide high quality boiler equipment and services for customers in different fields. We produce oil and gas boilers, biomass boilers, coal-fired boilers, which can be used in many fields such as food industry, paper industry, textile industry, heating industry, power generation industry, etc.The industrial boiler are developed with technical advantages, stable and reliable performance, exported to over 100 countries.

Whatever your requirements, you 'll find the perfect service-oriented solution to match your specific needs with our help. We are here for your questions anytime 24/7, welcome your consultation.

Send Inquiry

COMPANY INFORMATION

Note: If you're interested in the product, please submit your requirements and contacts and then we will contact you in two days. We promise that all your informations won't be leaked to anyone.

    • silica monitoring technical note on power plant

      Silica Monitoring TECHNICAL NOTE On Power Plant

      2018-5-9 · Silica build-up is monitored inside the boiler drum. The silica concentration is distributed between the water and vapour phases in a boiler. As the temperature and pressure are increased, more silica becomes present in the steam. In high pressure boilers, therefore, silica is appreciably concentrated in the steam and this is when

      Read More
    • scaling in boilers - lenntech

      Scaling in boilers - Lenntech

      If the silica enters the boiler water, the usual corrective action is to increase boiler blowdown, to decrease it to acceptable levels and then to correct the condition that caused the silica contamination. For further information check our web page about silica scaling in boilers.

      Read More
    • concentration control of silica in water chemical regime

      Concentration control of silica in water chemical regime

      Cited by: 2

      TECHNIFAX Selective silica carryover - steamforum

      2012-12-2 · type boilers confirmed that the 0.02 ppm figure is a valid and realistic maximum limit. Figure 2 High ratios of hydroxide alkalinity to silica in the boiler water reduce the ratio of silica Figure 5 — Silica in steam vs boiler pressure for pH = 11.3. ENHANCING CUSTOMER

      Read More
    • silica scaling in boilers - lenntech

      Silica Scaling in Boilers - Lenntech

      Silica, in amounts ranging from less than 1 to over 100 ppm, is found in all natural water supplies.In rain hail and snow, silica content range from 1 to 2.8 ppm. In the analyses of various surface and ground waters, silica content range from 1 to 107 ppm.This refers to soluble silica content and not to the silica that may be present in the suspended matter.

      Read More
    • water treatment for high pressure boilers in sugar plant

      Water Treatment for High Pressure Boilers in Sugar Plant

      2011-4-5 · Hence feed water is to be very pure for high pressure boilers. This, in turn, necessitates high purity for make-up water. Demineralisation can only produce acceptable make-up quality for high pressure boilers of the order of specific electrical conductivity less than 0.5 mmho/cm with hardness completely removed and silica less than 0.02 ppm. When

      Read More
    • steam purity - western regional boiler association home

      Steam Purity - Western Regional Boiler Association Home

      •Silica –normal saturated steam should be < 20 ppb in most boilers. High pH in the boiler water will reduce silica carryover from the boiler water. Monitor the steam because: •Precipitation of silica forms silicate deposits on the cold end of the turbine that are not water soluble and are very difficult to remove. The deposits may cause

      Read More
    • colloidal silica - treatment and removal

      Colloidal Silica - Treatment and Removal

      2013-2-5 · colloidal silica with 0.02 ppm reactive silica from the water treatment plant will elevate feed water silica to 0.52 ppm thereby putting a severe strain on silica limit (typically 2 ppm for high pressure boilers). Colloidal silica can cause serious problems of organic fouling of RO membranes because the

      Read More
    • high-pressure steam cycle and boiler water treatment

      High-Pressure Steam Cycle and Boiler Water Treatment

      2010-8-3 · •Pressure range – 60-84 bar • Critical needs – High quality makeup water • External pre-treatment through distillation and mechanical deaeration – High purity steam to the turbine – No excess hydrate alkalinity – Precise control of total system water treatment High Pressure Boilers • Steam cycle